Data Centre Cooling Optimization

Data center raised floors were initially developed to help to handle chiller lines, power feeds and most importantly the updraft required by mainframe equipment. Equipment needs, power and cooling requirements have changed significantly in data centers over the past 20 years since servers, storage and communication equipment started to occupy what was formerly occupied by mainframes and DASD equipment.

The original intent of the raised floor to cool the mainframe environment has since become a raceway for cabling runways, copper, fiber and power distribution in addition to the air flow.

Today's high density server farms, which are increasingly efficient heaters are requiring more power and cooling than ever before. The data center evolution of an all air cooled environment has become a real challenge for facility managers to deal with these heat related issues, cooling inefficiencies and increased server densities.

The challenge facility managers face is how to get the air that is beneath a raised the floor through the perforated tiles and into the front intakes of rack mounted vertically integrated server housings that are producing the heat.

Data Center Cooling Optimization Service

We offer a comprehensive cooling optimization service with a data-backed analytical approach using our wire-free environment monitoring solution. Visit our data center cooling optimization serivce page to learn more.


AisleLok Modular Containment: Rack Top Angle Baffle 10160

AisleLok Modular Containment: Rack Top Angle Baffle 10160

The AisleLok® Rack Top Baffles are a key component of Upsite’s AisleLok® Modular Containment solution and are available in two configurations: Angular (30° from horizontal) and Vertical (90° from horizontal).
AisleLok Modular Containment: Rack Top Vertical Baffle 10161

AisleLok Modular Containment: Rack Top Vertical Baffle 10161

The AisleLok Rack Top Baffles are a key component of Upsite’s AisleLok Modular Containment solution and are available in two configurations: Angular (30° from horizontal) and Vertical (90° from horizontal)
AisleLok Modular Containment Bi-Directional Doors 10163

AisleLok Modular Containment Bi-Directional Doors 10163

The AisleLok Bi-Directional Doors are a key component in Upsite’s AisleLok Modular Containment solution. The doors can be used with or without the AisleLok Rack Top Baffles; however, for maximum benefit both products are recommended.
AisleLok Adjustable Rack Gap Panel 10164

AisleLok Adjustable Rack Gap Panel 10164

The AisleLok Adjustable Rack Gap Panel is an ideal solution for closing off gaps between racks, such as spaces for building support columns. Closes gap widths from 10″ to 60″ wide (250-1500mm) with scrolling, adjustable panel. Features a tool-less des
AirBlock Expandable Filler Panels

AirBlock Expandable Filler Panels

Close the gaps in your data center with AirBlock EFP (Expandable Filler Panels). EFPs are designed to fill space between racks, power units, columns or other gaps in your data center where air can escape, reducing the effectiveness of your cooling efforts
AisleLok Under Rack Panel 10126 & 10127

AisleLok Under Rack Panel 10126 & 10127

Designed to seal a variety of openings below the rack on new and existing raised server racks, the Under Rack Panel will block bypass airflow and maximize cooling system efficiency of the data center. The AisleLok™ Under Rack Panel is the premium choic
AisleLok Acrycell Sealing Tape 10108

AisleLok Acrycell Sealing Tape 10108

AisleLok Acrycell Sealing Tape is the premium choice for sealing unusual gaps and openings in the data center including: Room perimeter Floor openings Under cabinets Between racks Around CRAC units Its revolutionary sealing technology greatly red
AirBlock Flexible  Gap Seals

AirBlock Flexible Gap Seals

Increase the cooling efficiency of your hot aisle/cold aisle isolation system and drastically reduce energy costs with QDS’s New Flexible Gap Seals (FGS).
AirBlock Rack Cap with Hard Top Panel or Melt-Away Tiles

AirBlock Rack Cap with Hard Top Panel or Melt-Away Tiles

Control temperatures in both hot aisle and cold aisle containment applications.
Chamfer ICE(TM) Airflow Panel

Chamfer ICE(TM) Airflow Panel

Triad's patented 56% high density airflow panels are designed to provide optimal data center and server farm
Data Center Curtains

Data Center Curtains

AirBlock data center curtains, and all Simplex materials, are made from virgin materials to provide extra clear transparency and protection against yellowing and cracking.
Heavy Duty Solid Panel

Heavy Duty Solid Panel

Triad's heavy duty solid panel is designed to provide optimal strength for both Imperial and Metric raised floor systems
HotLok Blanking Panels

HotLok Blanking Panels

HotLok Blanking Panel, the next-generation for IT equipment cabinets, is Upsite's latest green solution for energy consumption savings and reducing the carbon footprint of data centers. HotLok Blanking Panels can be used in most 19-inch EIA-210-E sta
HT 500 Smart Underfloor Air Mover

HT 500 Smart Underfloor Air Mover

Proper airflow distribution is the key to providing cooling to ever higher density server racks. Failure to deliver enough cooling air to rack intakes causes recirculation of hot air and
KoldLok Extended

KoldLok Extended

Designed to seal a variety of existing larger openings, with the added flexibility of modification for unique openings.
KoldLok Integral

KoldLok Integral

Airflow management device designed to seal cable openings in new raised-floor systems prior to the installation of communication or power cabling.
KoldLok Mini Raised Floor Grommet

KoldLok Mini Raised Floor Grommet

Install in new openings prior to the installation of equipment cables. Allows floor tiles to be moved without capturing cables.
KoldLok Round

KoldLok Round

Designed to seal openings in new and existing raised floor cutouts to block bypass airflow and maximize cooling system efficiency.
KoldLok Surface Mount

KoldLok Surface Mount

Designed to seal a variety of existing raised-floor tile cutouts and allow the flexibility of removing tiles without capturing cables. Item Nos. 2030 and 2040 allow for larger sealing capacities.
KoldLok Wave

KoldLok Wave

Designed to seal openings in new raised floor cutouts prior to the installation of communications, power, or other cabling. In a study done by Upsite Technologies on 19 computer rooms totaling over 204,400 ft2, it was found that 60% of valuable cooled a